OpenJAUS.com

This file is part of the OpenJAUS HTML JAUS Reference.
Please support AS-4 JAUS and SAE by purchasing the corresponding Standard Document(s) from SAE International here.

Home / Iop_v3ServiceSet / ReportLoggerConfiguration

Message ReportLoggerConfiguration

Message ID: 9212h

Description:
Report the configuration of a set of loggers

ReportLoggerConfiguration
LoggerConfigurationList
LoggerConfigurationRec
OverflowPolicyRec

Message Format
Field # Field Type Units Optional Interpretation
1 LoggerConfigurationList List false


LoggerConfigurationList
Count Field: Unsigned Byte
Field # Field Type Units Optional Interpretation
1 LoggerConfigurationRec Record false
2 OverflowPolicyRec Record false


LoggerConfigurationRec
Field # Field Type Units Optional Interpretation
1 LoggerID Byte units one false ID of the logger, 0 reserved to be all loggers
2 LoggingLevel BitField
Integer Size: Unsigned Byte
one false [0, 0] : LogVerbose (range: 0 ... 1)
[1, 1] : LogUnknown (range: 0 ... 1)
[2, 2] : LogCritical (range: 0 ... 1)
[3, 3] : LogError (range: 0 ... 1)
[4, 4] : LogWarning (range: 0 ... 1)
[5, 5] : LogInformation (range: 0 ... 1)
[6, 6] : LogDebug (range: 0 ... 1)


OverflowPolicyRec
Field # Field Type Units Optional Interpretation
1 Presence Vector Unsigned Byte one false Bit 0: OverflowLoggingLevel
Bit 1: OverflowSizeThreshold
Bit 2: OverflowPercentageThreshold
2 OverflowRemovalPolicy Enumeration
Integer Size: Unsigned Byte
one false Enumeration Values:
0: First_In_First_Out
1: Last_In_Last_Out
2: Least_Recently_Used
3: Most_Recently_Used
4: Least_Frequently_Used
5: Random_Replacement
3 OverflowLoggingLevel BitField
Integer Size: Unsigned Byte
one true [0, 0] : LogVerbose (range: 0 ... 1)
[1, 1] : LogUnknown (range: 0 ... 1)
[2, 2] : LogCritical (range: 0 ... 1)
[3, 3] : LogError (range: 0 ... 1)
[4, 4] : LogWarning (range: 0 ... 1)
[5, 5] : LogInformation (range: 0 ... 1)
[6, 6] : LogDebug (range: 0 ... 1)
4 OverflowSizeThreshold Unsigned Long units one true Size in MB
5 OverflowPercentageThreshold Scaled Integer
Integer Size: Unsigned Byte
units one true Real Lower Limit: 0.0
Real Upper Limit: 100.0



OpenJAUS.com