Message ReportSeismicSensorStatus

Message ID: DAB8h

Description:
This message is used to report the current status of one or more seismic sensors.

ReportSeismicSensorStatus
SeismicSensorStatusList
SeismicSensorStatusRec
SeismicSensorDataList
Intensity

Message Format
Field # Field Type Units Optional Interpretation
1 SeismicSensorStatusList List false


SeismicSensorStatusList
Count Field: Unsigned Byte
Field # Field Type Units Optional Interpretation
1 SeismicSensorStatusRec Record false
2 SeismicSensorDataList List false


SeismicSensorStatusRec
Field # Field Type Units Optional Interpretation
1 Presence Vector Unsigned Byte one false Bit 0: CoordinateFrameEnum
2 SensorID Unsigned Short units one false ID of the seismic sensor to be queried. A value of zero (0) is not permitted.
3 CoordinateFrameEnum Enumeration
Integer Size: Unsigned Byte
one true Enumeration Values:
0: SensorRelative
1: VehicleRelative
2: GlobalRelative


SeismicSensorDataList
Count Field: Unsigned Byte
Field # Field Type Units Optional Interpretation
1 Presence Vector Unsigned Byte one false Bit 0: Range
Bit 1: Bearing
Bit 2: Elevation
Bit 3: Intensity
Bit 4: Characterization
2 Range Scaled Integer
Integer Size: Unsigned Integer
units meter true distance to the detected seismic signal source

Real Lower Limit: 0.0
Real Upper Limit: 1000000.0
3 Bearing Scaled Integer
Integer Size: Unsigned Integer
units radians true bearing (rotation about the Z axis) to the detected seismic signal source

Real Lower Limit: -3.141592653589793
Real Upper Limit: 3.141592653589793
4 Elevation Scaled Integer
Integer Size: Unsigned Integer
units radians true elevation (rotation about the Y axis) to the detected seismic signal source

Real Lower Limit: -3.141592653589793
Real Upper Limit: 3.141592653589793
5 Intensity Variant varies true Magnitude of the detected seismic signal source
6 Characterization Enumeration
Integer Size: Unsigned Byte
one true Enumerated value list of the seismic classification, e.g. foot steps, car, etc

Enumeration Values:
0...99: Reserved for future IOP use
100...255: Reserved for project specific use


Intensity
Type Enum Size: Unsigned Byte
Enum Value Name Type Units Optional Interpretation
0 Option0 Float false
1 Option1 Float false



OpenJAUS.com

Copyright © SAE International. Reprinted with Permission.
Portions Copyright © OpenJAUS LLC.
The information above is generated from the JAUS Services modelled in the OpenJAUS SDK using OpenJAUS Service Studio. It is provided as a resource to assist JAUS developers and is not a substitute for the JAUS Standards Documents which may be obtained from the SAE International.

Generated on 07/17/2019 from iop_v3.ojss